Effect of Aortic Diameter and Systole Blood Pressure on Determination of CTA Coronary Pre-Delay Scan Bolus Trcking Technique

Authors

  • Arief Oesmanto Postgraduate Master of Diagnostic Imaging, Health Polytechnic Ministry of Health Semarang, Semarang, Central Java
  • A. Gunawan Santoso Postgraduate Master of Diagnostic Imaging, Health Polytechnic Ministry of Health Semarang, Semarang, Central Java
  • Darmini Postgraduate Master of Diagnostic Imaging, Health Polytechnic Ministry of Health Semarang, Semarang, Central Java
  • Ahmad Hariri Department of Radiodiagnostic and Radiotherapy Tehnique, STIKes Pertamedika, Jakarta

DOI:

https://doi.org/10.59890/ijnhs.v2i1.1210

Keywords:

Aortic Diameter, Bolus Tracking, CTA Coronaria, Pre-Delay Scan Time, Systolic Blood Pressure

Abstract

The variation in the pre-delay scan time of each individual on the CTA Caronaria check bolus tracking will contribute to the total acquisition time and vary the total amount of contrast and copy that must be provided during the acquisition.  This study aims to determine the effect of aortic diameter and systole blood pressure on pre-delay scan time. This research method is observational analytic with a retrospective crossectional approach measuring independent variables of aortic diameter and systole blood pressure. The result are the R Square value is 0.364. The regression coefficient value of  systole blood pressure (X1) is 0.043, the T value that was determined is 3. 102, and the significance value is 0.003. In addition, the computed T value is 3.597, the regression coefficient value of aortic diameter  (X2) is 0.256 and then we founded F value of regression model was 22.072.  As conclusion are Pre-delay scan duration is positively and significantly impacted by aorta diameter, systolic blood pressure has a positive and significant effect on pre-delay scan time and The two variables together have a positive and substantial effect on the pre-delay delay time. Additionally, this study discovered that other parameters controlled 63.6% of the deleye time of contrast material administration, with the remaining 36.4% being influenced by aortic diameter and systole blood pressure

References

Ajija, S. R., Sari, D. W., Setianto, R. H., & Primanti, M. R. (2011). Cara cerdas menguasai Eviews. Jakarta: Salemba Empat.

Bontrager, K. L. (2014). Text Book of Radiographic and Related Anatomy, Sevent Edition. St. Louis: Mosby Inc.

Boushra, N. N., & Muntazar, M. (2006). The role of statins in reducing perioperative cardiac risk: physiologic and clinical perspectives. Canadian Journal of Anesthesia, 53(11), 1126.

Efendi, A., Wardhani, N. W. S., Fitriani, R., & Sumarminingsih, E. (2020). Analisis regresi: teori dan aplikasi dengan R. Universitas Brawijaya Press.

Ernawati Waridah, S. S. (2017). Kamus Bahasa Indonesia. Bmedia.

Flohr, T. G., Schoepf, U. J., & Ohnesorge, B. M. (2007). Chasing the heart: new developments for cardiac CT. Journal of Thoracic Imaging, 22(1), 4–16.

Ghozali, I. (2018). Aplikasi analisis multivariete SPSS 25. Semarang: Universitas Diponegoro.

Goldstein, S. A., Evangelista, A., Abbara, S., Arai, A., Asch, F. M., Badano, L. P., Bolen, M. A., Connolly, H. M., Cuéllar-Calàbria, H., & Czerny, M. (2015). Multimodality imaging of diseases of the thoracic aorta in adults: from the American Society of Echocardiography and the European Association of Cardiovascular Imaging: endorsed by the Society of Cardiovascular Computed Tomography and Society for Cardiova. Journal of the American Society of Echocardiography, 28(2), 119–182.

Janir, D. (2012). Statistik deskriptif & regresi linier berganda dengan spss. In Semarang University Press (Issue April 2012).

Juliandi, A., & Manurung, S. (2014). Metodologi Penelitian Bisnis, Konsep dan Aplikasi: Sukses Menulis Skripsi & Tesis Mandiri. Umsu Press.

Magder, S. A. (2014). The highs and lows of blood pressure: toward meaningful clinical targets in patients with shock. Critical Care Medicine, 42(5), 1241–1251.

Marchal, G., Vogel, T. J., Heiken, J. P., & Rubin, G. D. (2005). Multidetector-Row Computed Tomography. Scanning and Contrast Protocols.: Springer, 1–133.

Nainggolan, F. (n.d.). 3D Anatomy Learning System Using Virtual Reality and VR Controller.

Neumann, F. J., Sechtem, U., Banning, A. P., Bonaros, N., Bueno, H., Bugiardini, R., Chieffo, A., Crea, F., Czerny, M., Delgado, V., Dendale, P., Knuuti, J., Wijns, W., Flachskampf, F. A., Gohlke, H., Grove, E. L., James, S., Katritsis, D., Landmesser, U., … Clapp, B. (2020). 2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes. European Heart Journal, 41(3), 407–477. https://doi.org/10.1093/eurheartj/ehz425

Pasteur-Rousseau, A., & Sebag, F. (2020). Cardiac CT-Scan: Utility for the management of chest pain, cardiovascular screening and before atrial fibrillation ablation procedure. Annales de Cardiologie et d’Angeiologie, 69(5), 276–288. https://doi.org/10.1016/j.ancard.2020.09.028

Saladin, K. S., & Porth, C. (2010). Anatomy & physiology: the unity of form and function (Vol. 5). McGraw-Hill New York.

Santoso, S. (2000). Latihan SPSS Statistik Parametrik. Jakarta: PT Elex Media Komputindo Gramedia.

Shinbane, J. S., Saxon, L. A., Doshi, R. N., Chang, P. M., & Budoff, M. J. (2016). CCTA Cardiac Electrophysiology Applications: Substrate Identification, Virtual Procedural Planning, and Procedural Facilitation. Cardiac CT Imaging: Diagnosis of Cardiovascular Disease, 455–486.

Sitepu, R. Y. (2021). Analisis Pertumbuhan Sektor Pertanian Di Kabupaten Langkat. Tesis, 6(2), 82–81.

Tang, L., Zhu, X., Xu, Y., Yu, T., Xu, H., Tang, J., Dogra, V., & Wang, D. (2011). Factors influencing delay time and coronary arterial density during coronary angiography with DSCT. Acta Radiologica, 52(1), 59–63. https://doi.org/10.1258/ar.2010.090465

Utami, H. S., Susanto, F., Oviyanti, P. N., & Purwokerto, U. M. (2022). Analysis of the Chest Msct Angiography Procedure With Bolus Tracking in the Massive Hemoptoe Case Analisis Prosedur Pemeriksaan Msct Angiografi Thorax Dengan Menggunakan Bolus Tracking. September, 42–48.

Wahyuni, M. (2020). Statistik Deskriptif Untuk Penelitian Olah Data Manual dan SPSS versi 25. In Angewandte Chemie International Edition, 6(11), 951–952. (Issue Mi).

Downloads

Published

2024-01-25